Intraocular Pressure Measured by Rebound Tonometry in Seven Raptor Species


Published: Jul 9, 2022
Keywords:
Intraocular pressure Raptor, Rebound tonometer
Muhammed Kaan YÖNEZ
https://orcid.org/0000-0001-9160-6363
M Erol
H Erol
G Atalan
Z Doğan
M Kibar
Abstract

In the present study, intraocular pressures (IOP) of 66 Buzzards (132 eyes), 20 Hawks (40 eyes), 13 Owls (26 eyes), 6 Eagles (12 eyes), 6 Kestrels (12 eyes), 4 Falcons (8 eyes), 2 Vultures (4 eyes), which referred to Erciyes University, Faculty of Veterinary Medicine, Department of Surgery Clinic were evaluated. In the ophthalmologic examination there was no lesion detected related to eyes. The mean body weight raptors was 1.10±0.23 kg (Buzzards), 0.23±0.06 kg (Hawks), 0.27±0.10 (Owls), 3.30±0.80 kg (Eagles), 0,18±0.04 kg (Kestrels), 0,64±0,28 kg (Falcons) and 2.28±0.43 kg (Vultures). Rebound tonometer (Tonovet) was used for measurement of IOP. Mean intraocular pressures of right and left eyes were in Buzzards 25.87±0.62-26.61±0.71, Hawks 11.90±0.40-12.05±0.41, Owls 12.00±0.63-12.61±0.57, Eagles 29.00±2.89-30.33±2.87, Kestrels 11.75±0.17-10.83±0.47, Falcons 14.75±1.10-14.25±0.85 and Vultures 15.00±1.00-14.50±0.50. As a result of the study, repeated intraocular pressure measurements of raptors can be made by using rebound tonometer. In addition, the application of rebound tonometer is very easy to application do not require local anaesthetic. Therefore, raptors may be able to tolerate the application easily. The present data are considered to contribute to the literature.

Article Details
  • Section
  • Research Articles
Downloads
Download data is not yet available.
Author Biography
Muhammed Kaan YÖNEZ, Erciyes University
Department of Surgery
References
Barsotti, G, Briganti, A, Spratte, JR, Ceccherelli, R, Breghi, G (2013) Schirmer tear test type I readings and intraocular pressure values assessed by applanation tonometry (XL Tonopent ) in normal eyes of four European species of birds of prey. Vet Ophthalmol 16(5):365–369.
Bliss, CD, Aquino, S, Woodhouse, S (2015) Ocular findings and reference values for selected ophthalmic diagnostic tests in the macaroni penguin (Eudypteschrysolophus) and southern rockhopper penguin (Eudypteschrysocome). Vet Ophthalmol 18(Suppl 1):86-93.
Broadwater, JJ, Schorling, JJ, Herring, IP, Pickett, JP (2007) Ophthalmic examination findings in adult pygmy goats (Capra hicus). Vet Ophthalmol 10(5):569-273.
Cheng, AC, Fan, D, Tang, E, Lam, DS (2006) Effect of corneal curvature and corneal thickness on the assessment of intraocular pressure using noncontact tonometry in patients after myopic LASIK surgery. Cornea 25(1):26-28.
Davidson, M (1997) Ocular consequences of trauma in raptors. Seminars in Avian and Exotic Pet Medicine 6(3):121-130.
Harris, MC, Schorling, JJ, Herring, IP, Elvinger, F, Bright, PR, Pickett, JP (2008) Ophthalmic examination findings in a colony of screech owls (Megascopsasio). Vet Ophthalmol 11(3):186-192.
Korbel, R, Braun, J (1999) Tonometry in birds using the Tonopen® XL. Tierarztl Prax Ausg K Kleintiere Heimtiere 27:208-217.
Kuhn, SE, Jones, MP, Hendrix, DVH, Ward, DA, Baine, KH (2013) Normal ocular parameters and characterization of ophthalmic lesions in a group of captive bald eagles (Haliaeetus leucocephalus). J Avian Med Surg 27(2):90-98.
Labelle, AL, Whittington, JK, Breaux, CB, Labelle, P, Mitchell, MA, Zarfoss, MK, Schmidt, SA, Hamor, RE (2012) Clinical utility of a complete diagnostic protocol for the ocular evaluation of free‐living raptors. Vet Ophthalmol 15(1):5-17.
Moore, BA, Teixeira, LBC, Sponsel, WE, Dubielzig, RR (2017) The consequences of avian ocular trauma: histopathological evidence and implications of acute and chronic disease. Vet Ophthalmol 20(6):496-504.
Murase, H, Sawada, A, Mochizuki, K, Yamamoto, E (2009) Effects of corneal thickness on intraocular pressure measured with three different tonometers. Jpn J Ophthalmol 53(1):1-6.
Reuter, A, Muller, K, Arndt, G, Eule, JC (2011) Reference intervals for intraocular pressure measured by rebound tonometry in ten raptor species and factors affecting the intraocular pressure. J Avian Med Surg 25(3):165-172.
Reuter, A, Muller, K, Arndt, G, Eule, JC (2010) Accuracy and reproducibility of the TonoVet rebound tonometer in birds of prey. Vet Ophthalmol 13(Suppl 80-5):80-85.
Seruca, C, Molina-Lopez, R, Pena, T, Leiva, M (2012) Ocular consequences of blunt trauma in two species of nocturnal raptors (Athene nocua and Otus scops). Vet Ophthalmol 15(4):236– 244.
Stiles, J, Buyukmihci, NC, Farver, TB (1994) Tonometry of normal eyes in raptors. Am J Vet Res 55(4):477-479.
Swinger, RL, Langan, JN, Hamor, R (2009) Ocular bacterial flora, tear production, and intraocular pressure in a captive flock of Humboldt penguins (Spheniscus humboldti). J Zoo Wildl Med 40(3):430-436.
Tonnu, PA, Ho, T, Newson, T, El Sheikh, A, Sharma, K, White, E, Bunce, C, Garway-Heath, D (2005) The influence of central corneal thickness and age on intraocular pressure measured by pneumotonometry, non-contact tonometry, the Tono-Pen XL, and Goldmann applanation tonometry. Br J Ophthalmol 89(7):851-854.