The purpose of the present study was to determine the alterations in haematological values at 0, 12, 24, 36, 48, 60, 72, 84 and 96 hours of storage in bovine and ovine venous blood samples stored at 4˚C and 24˚C in EDTA-coated tubes. Twenty healthy animals, including ten 4-year-old cattle and ten 2-year-old sheep constituted the study material. Bovine blood samples stored at 4˚C produced reliable results for the WBC, RBC, Hb, PCV, MCV, MCH and MCHC levels with the exception of PLT level as PLT levels decreased when the PLT stored 24 hours or longer times. On the other hand ovine blood samples stored at 4˚C for 24 hours or longer, all the parameters measured (WBC, RBC, Hb, PCV, MCV, MCH, MCHC and PLT levels) gave reliable results indicating that ovine blood parameters can be used effectively and safely. Furthermore, in the bovine blood samples, MCHC levels were decreased as from 60 hours stored at 24°C and WBC levels were decreased in the ovine blood samples stored 48 hours or longer at 24°C. However, the blood samples stored at 24°C, the measurement of the RBC, Hb, PCV, MCV, MCH and PLT levels produced reliable results.

Article Details
  • Rubrique
  • Research Articles
Téléchargements
Les données relatives au téléchargement ne sont pas encore disponibles.
Références
Athanasiou LV, Polizopoulou ZS, Kalafati MR, Ntararas G, Kontos V (2016) Effects of preanalytical handling on selected canine hematological parameters evaluated by automatic analyzer. Veterinary Research Forum, 2016.
Clark P, Mogg TD, Tvedten HW, Korcal D (2002) Artifactual changes in equine blood following storage, detected using the Advia 120 hematology analyzer. Vet Clin Pathol 31: 90-94.
De Baca ME, Gulati G, Kocher W, Schwarting R (2006) Effects of storage of blood at room temperature on hematologic parameters measured on Sysmex XE-2100. Labmedicine 37: 28-36.
Furlanello T, Tasca S, Caldin M, Carli E, Patron C, Tranquillo M, Lubas G, Solano-Gallego L (2006) Artifactual changes in canine blood following storage, detected using the ADVIA 120 henatology analyzer. Vet Clin Pathol 35: 42-46.
Gulati GL, Hyland LJ, Kocher W, Schwarting R (2002) Changes in automated complete blood cell count and differential leukocyte count results induced by storage of blood at room temperature. Arch Pathol lab Med 126: 336-42.
Hadzimusic N, Katica M, Muharemovic Z, Mušanovic J (2010) Effect of temperature storage on haematological parameters of avian turkey blood. IJCRIMPH 2: 158-166.
Hulme-Moir KL; Clark P, Spencer PBS (2006) Effects of temperature and duration of sample storage on the haematological characteristics of western grey kangaroos (Macropus fuliginosus). Aust Vet J 84: 143-147.
Ihedioha JI, Onwubuche RC (2007) Artifactual changes in PCV, hemoglobin concentration, and cell counts in bovine, caprine, and porcine blood stored at room and refrigerator temperatures. Vet Clin Pathol 36: 60-63.
Imeri F, Herklotz R, Risch L, Arbetsleitner C, Zerlauth M, Risch GM, Huber AR (2008) Stability of haematological analytes depends on the hematology analyser used: A stability study with Bayer Advia 120, Beckman Coulter LH 750 and Symex XE 2100. Clinica Chimica Acta 397: 68-71.
Kuipers H, Dubravčić-Šimunjak S, Moran J, Mitchell D, Shobe J, Sakai H, Ambartsumov R (2007) Effect of transport and delayed analysis on haematological variables in blood samples taken from elite speed skaters. Hrvat Športskomed Vjesn 22: 71-75.
Mahmoodi M, Hajizadeh M, Rashidinejad H, Asadikaram G, Khaksari M, Mirzaee M, Seyedi N, Rahnema A, Sayadi A (2006) Survey of changes incomplete blood count and red cell indices of whole blood incubated in vitro at different temperatures up to 48 hours. J Ayub Med Coll Abbottabad 18: 14-16.
Médaille C, Briend-Marchal A, Braun JP (2006) Stability of selected hematology variables in canine blood kept at room temperature in EDTA for 24 and 48 hours. Vet Clin Pathol 35: 18-23.
Olsen AK, Bladbjerg EM, Jensen AL, Hansen AK (2001) Effect of preanalytical handling on haematological variables in minipigs. Lab Anim 35: 147-152.
Pait G, Semalulu S, Florence Z, Nolan J (1994) Stability of haematological parameters in Woodland Caribou (Rangifer tarandus caribou) blood stored at 4ºC. The Sixth North American Caribou Workshop, Prince George, British Columbia, Canada,pp, 297-300, 1-4 March.